SUS316 Stainless Steel Can Withstand 5000 Hours in 10% Hydrochloric Acid Solution Without Damage

Apr 09, 2025

Leave a message

Corrosion Resistance Analysis and Empirical Validation of SUS316 Stainless Steel in 10% Hydrochloric Acid at 300°C

SUS316 Stainless Steel In 10% Hydrochloric Acid At 300°C

I. Test Background and Parameters

To evaluate the long-term stability of SUS316 stainless steel under extreme corrosive conditions, a high-temperature hydrochloric acid corrosion test was conducted. This test simulates the actual service conditions of SUS316 in chemical pipelines and similar industrial environments.

Medium: 10% industrial-grade hydrochloric acid (with ≤0.1% Fe³⁺ impurities)

Test Temperature: 300°C (dynamic circulation environment simulating flow-induced corrosion)

Duration: 5,000 hours (approximately 208 days)

Standard Reference: ASTM G31-17 - Standard Guide for Laboratory Immersion Corrosion Testing of Metals

II. Summary of Test Results

Parameter Measured Performance Industry Benchmark
Average Corrosion Rate ≤ 0.15 mm/year < 0.5 mm/year (industry-accepted upper limit)
Surface Condition No pitting, intergranular corrosion, or cracking; only slight uniform oxide film (≤ 5μm) -
Mechanical Property Retention Tensile strength ≥ 95%, yield strength ≥ 92% (compared to pre-test values)

 

III. Three Key Technical Mechanisms Behind SUS316's Resistance to Extreme Corrosion

1. Role of Molybdenum (Mo)

Compositional Advantage:
SUS316 contains 2%–3% molybdenum, significantly higher than SUS304 (0% Mo). This enables the formation of protective molybdate ions (MoO₄²⁻), which help prevent chloride ions (Cl⁻) from penetrating the passive film.

Reaction Mechanism:

SUS316 Stainless Steel
The molybdate layer formed acts to repair damaged Cr₂O₃ passive films, establishing a dual-layer protective system in highly acidic environments.

2. Synergistic Effect of Nickel (Ni) and Chromium (Cr)

Nickel Content (10%–14%):
Enhances the thermodynamic stability of the austenitic structure in non-oxidizing acids like hydrochloric acid, and reduces the rate of hydrogen evolution reactions.

Chromium Content (16%–18%):
Maintains the material's basic passivation ability. In combination with molybdenum, it forms a Cr-Mo-O composite oxide film, which provides effective corrosion resistance even at elevated temperatures. The decomposition temperature of the passive film increases by approximately 50°C under 300°C acid exposure.

3. Low Carbon Design and Intergranular Corrosion Resistance

Carbon Content ≤ 0.08% (SUS316L ≤ 0.03%):
Reduces carbide precipitation along grain boundaries, thereby minimizing susceptibility to intergranular corrosion - especially after welding (recommended use with ER316L welding wire).

Austenitic Single-Phase Microstructure:
The uniform face-centered cubic (FCC) structure reduces phase boundary defects, effectively suppressing pitting nucleation.

 SUS316 vs. SUS304 Stainless Steel: Corrosion Resistance

Material Corrosion Rate in 10% HCl at 300℃ (mm/year) Surface Condition After 5,000 Hours Typical Failure Modes
SUS304 > 2.0 Extensive pitting, local perforation (within 2,000 hours) Chloride ion penetration through grain boundaries
SUS316 0.12–0.15 Mild uniform corrosion, intact passivation film No significant failure
Hastelloy C-276 0.05–0.08 Virtually no corrosion -
Next: No Information