ASTM B862 Ti2 (UNS R50400) Titanium Alloy Welded Pipe: Properties and Applications

Oct 28, 2025

Leave a message

What Is ASTM B862 Ti2 Welded Pipe?

ASTM B862 is the specification that covers welded titanium and titanium alloy pipe for general corrosion-resisting and elevated-temperature service. Grade 2, also written Ti2 or UNS R50400, is commercially pure unalloyed titanium with a titanium content of at least 99.2%. The balance consists of controlled levels of iron, oxygen, carbon, nitrogen and hydrogen.

The pipe is manufactured from flat-rolled titanium strip, formed into a cylinder and welded longitudinally, most commonly by gas tungsten arc welding (GTAW/TIG) or plasma arc welding. The weld must meet the same tensile requirements as the base metal, and the finished pipe is supplied in the welded, annealed or welded-and-cold-worked condition depending on the purchase specification.

Chemical Composition (ASTM B862 / B265)

Grade 2 is defined by tight impurity limits, since the mechanical and corrosion properties of unalloyed titanium depend strongly on interstitial elements, especially oxygen.

Element N C H Fe O Ti
Content, % 0.03 max 0.08 max 0.015 max 0.30 max 0.25 max Balance (99.2 min)

Mechanical Properties (ASTM B862 Grade 2)

Property Requirement
Tensile strength Rm 345 MPa (50 ksi) min
0.2% yield strength Rp0.2 275 MPa (40 ksi) min
Elongation in 50 mm or 4D 20% min
Reduction of area 30% min
Density 4.51 g/cm3
Melting point approximately 1668 degrees C

Grade 2 has a good combination of strength and ductility for a commercially pure grade. At roughly 4.5 g/cm3, it is only about 57% of the weight of steel, which gives titanium pipe a strong strength-to-weight advantage in structural and rotating equipment.

Manufacture and Welding Considerations

Welded Grade 2 pipe is made from cold-rolled strip, edge-prepared and welded by GTAW or plasma arc welding. For most applications, ERTi-2 filler wire (AWS A5.16) is used so that the weld metal matches the base metal properties.

Titanium is highly reactive at elevated temperature. Above roughly 500 degrees Celsius it absorbs oxygen, nitrogen and hydrogen from the atmosphere, which embrittles the weld and heat-affected zone. Welding must therefore be carried out with inert gas shielding of high-purity argon (99.99% or better) on both the face and the root of the weld, and shielding must be maintained until the weld area cools below about 400 degrees Celsius. Proper shielding is the single most important factor in producing sound titanium welds.

Corrosion Resistance

Commercially pure titanium Grade 2 has excellent corrosion resistance in seawater, brackish water, chloride solutions and most oxidizing media. It is immune to chloride stress corrosion cracking and does not suffer pitting or crevice corrosion in natural seawater. It also resists oxidizing acids such as nitric acid, and many organic acids and alkalis.

In seawater heat exchangers and condensers, Grade 2 titanium pipe typically provides much longer service life than austenitic stainless steel, which is why it is widely specified in power plants, desalination facilities and shipboard systems. The material is not suitable for strongly reducing media such as hot concentrated hydrochloric or sulfuric acid without alloying, and it should not be used above about 300-400 degrees Celsius in air because of oxidation and oxygen absorption.

Typical Applications

Chemical process piping for chlorides, oxidizing acids and bleach liquors.

Seawater cooling and firewater systems on ships and offshore platforms.

Heat exchangers and condensers in power generation and desalination.

Pulp and paper bleaching plants.

Electroplating and metal finishing equipment.

Pharmaceutical and food processing lines requiring high purity.

Frequently Asked Questions

Q1. What is the difference between titanium Grade 1 and Grade 2?

Both are commercially pure. Grade 1 has lower interstitial oxygen content and is softer and more formable, with a minimum tensile strength of about 240 MPa. Grade 2 has a minimum tensile strength of 345 MPa and is the most widely used commercially pure grade, balancing strength, ductility and corrosion resistance.

Q2. Why is high-purity argon required when welding titanium?

Molten and hot titanium absorbs oxygen, nitrogen and hydrogen very rapidly. These elements form hard, brittle phases that crack under load. Shielding with argon of 99.99% purity or higher prevents atmospheric contamination of the weld and heat-affected zone.

Q3. Can Grade 2 titanium welded pipe be used in seawater?

Yes. Grade 2 is one of the most reliable materials for seawater service. It is resistant to pitting, crevice corrosion and stress corrosion cracking in natural seawater and is widely used in seawater heat exchangers, piping and marine equipment.

Q4. What is the difference between ASTM B861 and B862?

ASTM B861 covers seamless titanium and titanium alloy pipe, while ASTM B862 covers welded pipe. Both share the same grade designations and chemical and mechanical requirements for the base metal; the difference is the manufacturing process.

Q5. Is Grade 2 titanium magnetic?

No. Titanium and its alloys are essentially non-magnetic (paramagnetic), which makes them useful in instrumentation, medical and marine applications where magnetic interference must be avoided.

Q6. What filler metal is used to weld Grade 2 pipe?

ERTi-2 filler wire, classified under AWS A5.16, is normally used so that the weld metal matches the mechanical properties and corrosion resistance of the Grade 2 base material.

Send Inquiry